| Sample holders - Custom sample holders available on request. | |||||
2 |
No1 |
200 Step |
114mm x 75mm Stages fitted with adjustable limit switches. |
Petri/Slide/Microtitre: |
|
1 |
No1 |
200 Step |
|||
2 |
Yes |
200 Step |
|||
1 |
Yes |
200 Step |
|||
1 |
No1 |
400 Step |
|||
|
1 |
Yes |
400 Step |
For Cambridge Circular style connectors for connection to controller add CC to the end of the end of the part number.
For Manual Knobs on the motors for turning by hand add K to the end of the part number.
| Sample holders - Custom sample holders available on request. | |||||
2 |
No |
200 Step |
|
Holders for H138 Stage:
|
|
2 |
Yes |
200 Step |
For Cambridge Circular style connectors for connection to controller add CC to the end of the end of the part number.
For Manual Knobs on the motors for turning by hand add K to the end of the part number.
Please order part no of stage and part number of sample holder, (don't forget the controller).
Motorised Focus Control: Z axis.
| Focus Motor | Part Number: PS3H122 Direct Couple kit available - Order additional PS3H122KON |
Focus sleeve | Part Number: H556 Fitting instructions available on website/ProScan Manual |
| ![]() |
|||||||||
Please order Focus Motor and sleeve part numbers, e.g., PS3H122 and H556.
Piezo Motorised Focus (NanoScanZ).
|
![]() |
Laser Autofocus.
*
Choose from NanoScanZ section above. |
![]() ![]() |
||||||||||||||||||||
Motorised Filter Wheels and Shutters.
| Position on Microscope | Filter wheel and Adaptor Part Number | Description | Shutter for filter wheel Part Number | Stand alone shutter and adaptor Part Number | Description |
| Excitation (e.g., Fluorescence light source) | HF110A HF220 |
10 position filter wheel, 25mm filters. | HF200HT |
HF202HT HF220 |
32mm high temperature shutter. |
| Excitation (e.g., Fluorescence light source) | HF108A HF220 |
8 position filter wheel, 32mm filters. | HF201HT |
HF204HT HF220 |
32mm high temperature shutter. |
| Excitation (e.g., Fluorescence light source) | L200PNI | Lumen light source with internal 6 position filter wheel. | Supplied with Lumen | Not Applicable | Light attenuation, 0-100% light control. |
| Emission (e.g., light to camera) | HF110A HF223 |
10 position filter wheel, 25mm filters. | HF200 |
HF202 |
25mm shutter |
| Brightfield or transmitted light. | HF108A (See Note) |
8 position filter wheel, 32mm filters. |
HF201 | HF204 |
32mm high temperature shutter. |
Note: If using Nikon C-LP Pre-centred lamphouse use adapter HF226. If using C-LC Centring lamphouse use adapter HF220.
Please order the filterwheel or shutter and required adaptor, e.g., Excitation filter wheel and shutter: HF108A, HF220 and HF201HT.
A filter wheel stand (HF310) may be used for added stability depending on microscope configuration where space allows.
|
![]() |
ProScan Motorised System Controller.
Joysticks.
| PS3J100 | Interactive Control Centre (ICC) for the control of all axes including; |
![]() |
||||||||
| CS152DP | Joystick to control XYZ axes. | |||||||||
System Controller.
Select the controller required from the matrix below. Choose between Horizontal (H) and Vertically (V) expanding systems.
Horizontally mounted: |
Equipment controlled | Vertically mounted: |
Equipment controlled | ||
| H31XYZ |
Stage and Focus | ![]() |
V31XYZ |
Stage and Focus | ![]() |
| H31XYZE |
Encoded Stage and Encoded Focus | ![]() |
V31XYZE |
Encoded Stage and Encoded Focus | ![]() |
| H31XYZF | Stage and Focus plus 3 filter wheels and 3 shutters | ![]() |
V31XYZF | Stage and Focus plus 3 filter wheels and 3 shutters | ![]() |
| H31XYZEF | Encoded Stage and Encoded Focus plus 3 filter wheels and 3 shutters |
![]() |
V31XYZEF | Encoded Stage and Encoded Focus plus 3 filter wheels and 3 shutters |
![]() |
| H31F | 3 Filter wheels and 3 Shutters |
![]() |
V31F | 3 Filter wheels Shutters |
![]() |
Notes:
For Focus only solutions choose the ES10ZE controller |
![]() |