Nikon Eclipse E800 Upright Microscope Upright Microscope

Motorised Stage Control: XY axis.

Stage part Number
Ball Screw Size
Linear Encoded
Motor Type
Travel Range
Sample holders - Custom sample holders available on request.
Most Popular Upright Stage, a good balance between accuracy and speed.
2
No1
200 Step

H101A Stage

114mm x 75mm

Stages fitted with adjustable limit switches.

Petri/Slide/Microtitre:
H224PLP Slide holder, Semi-recessed, for one 76 x 26mm microscope slide
H234PLP Slide holder, Semi-recessed, for four 76 x 26mm microscope slides
H236PRV Chambered Coverslip Slide Holder, Semi-recessed, Holds Four Lab-Tek Slides
H223R Recessed microtitre plate holder ( 85 x 128mm )
H237PLP
Slide holder, Semi-recessed, for one 76 x 51mm microscope slide
Solid Holders:
H220 Glass plate ( not suitable for transmitted light microscopy )
H230 Aluminium plate
Metallurgical Holders:
H649 Holder for a single 1", 1.25" and 1.5" Mounted Metallurgical Specimen
H656 Holder for One Mounted Metallurgical Specimen, 1.25" Diameter
H657 Holder for One Mounted Metallurgical Specimen, 2" Diameter
H658 Holder for Six Mounted Metallurgical Specimens, 1.25" Diameter
H659 Holder for One Mounted Metallurgical Specimen, 1.5" Diameter with 1, 2, 4 or 8 Chambers

1mm Ball Screw provides a more accurate stage
1
No1
200 Step
Encoded Verison of H101BX
2
Yes
200 Step
Encoded Version of H1P1BX
1
Yes
200 Step
Most accurate non-encoded stage.
1
No1
400 Step

Most accurate, with most smooth movement stage with encoders.

1
Yes
400 Step

For Cambridge Circular style connectors for connection to controller add CC to the end of the end of the part number.
For Manual Knobs on the motors for turning by hand add K to the end of the part number.

Stage part Number
Ball Screw Size
Linear Encoded
Motor Type
Travel Range
Sample holders - Custom sample holders available on request.
Most Polpular Stage, a good balance of accuracy and speed.
2
No
200 Step

H138a Stage
240mm x 71mm
Stages fitted with adjustable limit switches.

Holders for H138 Stage:


H238PLP Slide Holder for Eight 76x26mm Microscope Slides, semi-recessed
H239 Aluminium Plate
H288 Glass Plate (not suitable for transmitted light microscopy)

Encoded Version
2
Yes
200 Step

For Cambridge Circular style connectors for connection to controller add CC to the end of the end of the part number.
For Manual Knobs on the motors for turning by hand add K to the end of the part number.

Please order part no of stage and part number of sample holder, (don't forget the controller).

Back to top.

Motorised Focus Control: Z axis.

Focus Motor

Part Number: PS3H122
For Rotary encoded Version use: PS3H122E
Standard Motor -Requires focus sleeve.

Direct Couple kit available - Order additional PS3H122KON

Focus sleeve

Part Number: H556

Fitting instructions available on website/ProScan Manual

Linear encoder focus probe available: Part Numbers:
  H393 - Encoder Probe
  H394 - Encode Probe fixing kit
For encoded systems add "E" to Controller Part Number.
H122 Focus Motor

Please order Focus Motor and sleeve part numbers, e.g., PS3H122 and H556.

Piezo Motorised Focus (NanoScanZ).

Travel Range 100um 200um 250um 500um
Part Numbers to fit to H117 Stages NZ100 NZ200 NZ250 NZ500
Universal holder.     NZ302 NZ302
Microtitre plate holder ( 85 x 128mm )     NZ301 NZ301
Universal holder, slide or 35mm Petri Dish H499 H499    
Slide holder H471 H471    
35mm Petri dish holder H472 H472    
Manual Stage Adaptor N/A     N/A
Incubator for 35mm Petri Dish N/A     N/A
NanoScanZ

Laser Autofocus.

  Laser focus with Peizo Laser Focus with standard focus motor
Laser focus unit
LF210
LF210
Keypad
N/A
LF100K
Focus mechanism
NanoScanZ*
H122
H556
Adaptor
LF320
LF305
LF320

* Choose from NanoScanZ section above.

Laser FocusKeypad

 

Back to top.

Motorised Filter Wheels and Shutters.

Position on Microscope Filter wheel and Adaptor Part Number Description Shutter for filter wheel Part Number Stand alone shutter and adaptor Part Number Description
Excitation (e.g., Fluorescence light source) HF110A
HF220
10 position filter wheel, 25mm filters. HF200HT
HF202HT
HF220
32mm high temperature shutter.
Excitation (e.g., Fluorescence light source) HF108A
HF220
8 position filter wheel, 32mm filters. HF201HT
HF204HT
HF220
32mm high temperature shutter.
Excitation (e.g., Fluorescence light source) L200PNI Lumen light source with internal 6 position filter wheel. Supplied with Lumen Not Applicable Light attenuation, 0-100% light control.
Emission (e.g., light to camera) HF110A
HF223
10 position filter wheel, 25mm filters. HF200

HF202
HF223

25mm shutter
Brightfield or transmitted light. HF108A
(See Note)
8 position filter wheel, 32mm filters.
HF201

HF204
(See Note)

32mm high temperature shutter.
 

Note: If using Nikon C-LP Pre-centred lamphouse use adapter HF226. If using C-LC Centring lamphouse use adapter HF220.

Please order the filterwheel or shutter and required adaptor, e.g., Excitation filter wheel and shutter: HF108A, HF220 and HF201HT.
A filter wheel stand (HF310) may be used for added stability depending on microscope configuration where space allows.

Back to top.

Fluorescence light source.

Manual shutter Motorised filter wheel and light attenuation Description
L200NI L200PNI Optimised for general microscopy use
L210NI L210PNI Extended wavelength
for CY5 and CY5.5
L220NI L220PNI Extended wavelength
UV and IR

 
Lumen 200

Back to top.

ProScan Motorised System Controller.

Joysticks.

PS3J100

Interactive Control Centre (ICC) for the control of all axes including;
filter wheel's, shutters, stages, focus, LumenPro and fourth axis accessories with measurement facilities.

Interactive Control Centre
   
CS152DP Joystick to control XYZ axes.  

System Controller.

Select the controller required from the matrix below. Choose between Horizontal (H) and Vertically (V) expanding systems.

Horizontally mounted:
Model Number

Equipment controlled  

Vertically mounted:
Model Number

Equipment controlled  
H31XYZ
Stage and Focus PS3 Cube V31XYZ
Stage and Focus PS3 Cube
H31XYZE
Encoded Stage and Encoded Focus PS3 Cube V31XYZE
Encoded Stage and Encoded Focus PS3 Cube
H31XYZF Stage and Focus plus 3 filter wheels and 3 shutters Horizontal PS3
V31XYZF Stage and Focus plus 3 filter wheels and 3 shutters Vertical addon
H31XYZEF Encoded Stage and Encoded Focus plus 3 filter wheels and 3 shutters
Horizontal PS3 V31XYZEF Encoded Stage and Encoded Focus plus 3 filter wheels and 3 shutters
Vertical addon
H31F 3 Filter wheels and 3 Shutters
PS3 Cube V31F 3 Filter wheels Shutters
PS3 Cube

Notes:

For Focus only solutions choose the ES10ZE controller

ProScan II

Back to top.